Mfg Part Number: 63-010 | Alternate P/N: 63010 | Manufacturer: Lindgren Rf Enclosures Inc |
NSN : 5915-00-166-8166 | NIIN : 001668166 | Item Name : Filter Radio Freque |
CAGE Code : 29098 | FSC : 5915 Filters and Networks |
We’re happy to announce that part number 63-010 with NSN 5915001668166 under FSC 5915 Filters and Networks is now available in our ready-to-ship inventory. Manufactured by Lindgren Rf Enclosures Inc under (CAGE Code 29098), this part is a Filter Radio Freque. Would you like a quick quote for this part number? Just fill out the form to get started.
Your quote will be calculated on the basis of your answers to asterisk-marked (*) fields such as Needs Parts By and Quantity (ea), so make sure that you fill them out completely. A dedicated sales representative will respond to your RFQ by email or by phone within 15 minutes of receiving this form.
NSN Purchasing, owned and operated by ASAP Semiconductor, is a leading supplier of NSN part 63-010 from Lindgren Rf Enclosures Inc, alongwith more than 2 billion NSN parts in stock. We are an AS9120B, ISO 9001:2015 certified and FAA AC-0056B accredited company. Our vast inventory of ready-to-ship parts and key presence in various locations across the continental US and Canada allow us to fulfill AOG requirements swiftly and efficiently. We also offer same day shipping and next day shipping.
The National Stock Number, also known as NSN, is recognized and utilized as a cataloging system for procuring, stocking, and issuing items by all members of the North Atlantic Treaty Organization (NATO) and the United States’ Department of Defense (DoD). To learn more about 63-010 with NSN 5915001668166, call us at our toll-free number +1-714-705-4780, or email us at sales@nsnpurchasing.com
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-166-8166 Item Description: Filter Radio Freque | 5915 | 001668166 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
7 | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
63-010 | 6 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
ABKW | OVERALL HEIGHT | 2.250 INCHES MAXIMUM |
ADAQ | BODY LENGTH | 6.220 INCHES MINIMUM AND 6.280 INCHES MAXIMUM |
ADAT | BODY WIDTH | 1.440 INCHES MINIMUM AND 1.500 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.770 INCHES MINIMUM AND 1.830 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 5.820 INCHES MINIMUM AND 5.840 INCHES MAXIMUM |
AECR | VIBRATION RESISTANCE RANGE IN HERTZ | +10.0/+2000.0 |
AFGA | OPERATING TEMP RANGE | -55.0/+95.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 1ST RADIO INTERFERENCE |
AHBB | POWER LINE FREQUENCY RATING PER FUNCTION IN HERTZ | 400.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.0 2ND RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 2.5 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 400.0 MILLIVOLTS AC 2ND RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS AC 1ST RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS DC 3RD RADIO INTERFERENCE |
AHBE | MAXIMUM VOLTAGE DROP PER FUNCTION | 750.0 MILLIVOLTS DC 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | ENCASED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 2 THREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 4 TAB, SOLDER LUG OUTPUT 2ND FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 5 TAB, SOLDER LUG INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 7 TURRET GROUND 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 115.0 VOLTS AC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 26.0 VOLTS AC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.138 INCHES |
CRDC | MAXIMUM DIELECTRIC WITHSTANDING DC VOLTAGE | 322.0 VOLTS AT SEA LEVEL |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON ONE SURFACE |
63-0-47-03-02 | 63-0-5-00 | 63-0-5-00 | 63-0-5-00 |
63-00-3 | 63-00-3 | 63-000-1773 | 63 000 859 |
63 000 860 | 63 000 861 | 63 000 931 | 63-0000-00 |
63-0000-1589 | 63-00003-001 | 63-00003-001 | 63-00003-001 |
Before You Go, Please Take a Look at NSN Parts Catalog!
Request for Quote