Mfg Part Number: 05144 | Manufacturer: General Dynamics Land Systems | NSN : 5950-01-340-8672 |
NIIN : 013408672 | Item Name : Reactor | CAGE Code : 13160 |
FSC : 5950 Coils and Transformers |
We’re happy to announce that part number 05144 with NSN 5950013408672 under FSC 5950 Coils and Transformers is now available in our ready-to-ship inventory. Manufactured by General Dynamics Land Systems under (CAGE Code 13160), this part is a Reactor. Would you like a quick quote for this part number? Just fill out the form to get started.
Your quote will be calculated on the basis of your answers to asterisk-marked (*) fields such as Needs Parts By and Quantity (ea), so make sure that you fill them out completely. A dedicated sales representative will respond to your RFQ by email or by phone within 15 minutes of receiving this form.
NSN Purchasing, owned and operated by ASAP Semiconductor, is a leading supplier of NSN part 05144 from General Dynamics Land Systems, alongwith more than 2 billion NSN parts in stock. We are an AS9120B, ISO 9001:2015 certified and FAA AC-0056B accredited company. Our vast inventory of ready-to-ship parts and key presence in various locations across the continental US and Canada allow us to fulfill AOG requirements swiftly and efficiently. We also offer same day shipping and next day shipping.
The National Stock Number, also known as NSN, is recognized and utilized as a cataloging system for procuring, stocking, and issuing items by all members of the North Atlantic Treaty Organization (NATO) and the United States’ Department of Defense (DoD). To learn more about 05144 with NSN 5950013408672, call us at our toll-free number +1-714-705-4780, or email us at sales@nsnpurchasing.com
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5950-01-340-8672 Item Description: Reactor | 5950 | 013408672 | 0 | P | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | A | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
05144 | 5 | 2 | 3 |
MRC | Criteria | Characteristic |
---|---|---|
AARG | RELIABILITY INDICATOR | NOT ESTABLISHED |
ABHY | TURN QUANTITY | 22 SINGLE COMPONENT 1ST WINDING156 SINGLE COMPONENT 2ND WINDING |
ACYF | INDUCTANCE TYPE | SWINGING |
ACYV | INDUCTANCE RATING | 28.00 MICROHENRIES MINIMUM SINGLE COMPONENT 1ST WINDING AND 35.00 MICROHENRIES MAXIMUM SINGLE COMPONENT 1ST WINDING800.00 MICROHENRIES MINIMUM SINGLE COMPONENT 2ND WINDING AND 900.00 MICROHENRIES MAXIMUM SINGLE COMPONENT 2ND WINDING |
ACZB | FREQUENCY RATING | 20.0 KILOHERTZ NOMINAL SINGLE COMPONENT |
ADAQ | BODY LENGTH | 1.000 INCHES MAXIMUM |
ADAV | OVERALL DIAMETER | 0.970 INCHES MINIMUM AND 1.030 INCHES MAXIMUM |
AEHZ | MAXIMUM OPERATING TEMP | 155.0 DEG CELSIUS |
AKDX | WINDING QUANTITY | 2 SINGLE COMPONENT |
AKNA | INCLOSURE TYPE | FULLY INCLOSED |
AKPV | MOUNTING FACILITY QUANTITY | 1 SINGLE GROUP |
AXGY | MOUNTING METHOD | THREADED HOLE SINGLE GROUP |
BKPL | RATING METHOD | ELECTRICAL SINGLE COMPONENT ALL WINDING AND WINDING TURNS SINGLE COMPONENT ALL WINDING |
CBBL | FEATURES PROVIDED | TINNED WIRE LEADS |
CQPZ | WINDING CONDUCTOR SIZE | 0.03589 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 1ST WINDING0.01594 INCHES AMERICAN WIRE GAGE SINGLE COMPONENT 2ND WINDING |
CRBZ | WINDING OPERATING CURRENT | 3.5 AMPERES DC MAXIMUM SINGLE COMPONENT 1ST WINDING300.0 MILLIAMPERES DC MAXIMUM SINGLE COMPONENT 2ND WINDING |
CRGS | DC RESISTANCE RATING IN OHMS | 0.020 SINGLE COMPONENT 1ST WINDING0.620 SINGLE COMPONENT 2ND WINDING |
TEST | TEST DATA DOCUMENT | 13160-7573760 DRAWING (THIS IS THE BASIC GOVERNING DRAWING, SUCH AS A CONTRACTOR DRAWING, ORIGINAL EQUIPMENT MANUFACTURER DRAWING, ETC.; EXCLUDES ANY SPECIFICATION, STANDARD OR OTHER DOCUMENT THAT MAY BE REFERENCED IN A BASIC GOVERNING DRAW |
TTQY | TERMINAL TYPE AND QUANTITY | 4 WIRE LEAD |