NIIN : 009013751 | Item Name : Filter Radio Freque | CAGE Code : 56289 |
FSC : 5915 Filters and Networks |
We’re happy to announce that part number RF00159 with NSN 5915009013751 under FSC 5915 Filters and Networks is now available in our ready-to-ship inventory. Manufactured by Sprague Electric Co World Hqs under (CAGE Code 56289), this part is a Filter Radio Freque. Would you like a quick quote for this part number? Just fill out the form to get started.
Your quote will be calculated on the basis of your answers to asterisk-marked (*) fields such as Needs Parts By and Quantity (ea), so make sure that you fill them out completely. A dedicated sales representative will respond to your RFQ by email or by phone within 15 minutes of receiving this form.
NSN Purchasing, owned and operated by ASAP Semiconductor, is a leading supplier of NSN part RF00159 from Sprague Electric Co World Hqs, alongwith more than 2 billion NSN parts in stock. We are an AS9120B, ISO 9001:2015 certified and FAA AC-0056B accredited company. Our vast inventory of ready-to-ship parts and key presence in various locations across the continental US and Canada allow us to fulfill AOG requirements swiftly and efficiently. We also offer same day shipping and next day shipping.
The National Stock Number, also known as NSN, is recognized and utilized as a cataloging system for procuring, stocking, and issuing items by all members of the North Atlantic Treaty Organization (NATO) and the United States’ Department of Defense (DoD). To learn more about RF00159 with NSN 5915009013751, call us at our toll-free number +1-714-705-4780, or email us at sales@nsnpurchasing.com
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5915-00-901-3751 Item Description: Filter Radio Freque | 5915 | 009013751 | 0 | Y | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
Rf00159 | 2 | 2 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 6.938 INCHES NOMINAL |
ADAQ | BODY LENGTH | 6.000 INCHES NOMINAL |
ADAT | BODY WIDTH | 4.030 INCHES MAXIMUM |
ADAU | BODY HEIGHT | 1.550 INCHES MAXIMUM |
AEBY | DISTANCE BETWEEN CENTERLINES OF MOUNTING FACILITIES PARALLEL TO BODY LENGTH | 3.250 INCHES NOMINAL |
AFGA | OPERATING TEMP RANGE | -55.0/+85.0 DEG CELSIUS |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAQ | SOURCE IMPEDANCE RATING PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 1ST RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 2ND RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 3RD RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 4TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 5TH RADIO INTERFERENCE |
AHAS | LOAD IMPEDANCE PER FUNCTION | 50.0 OHMS 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 3RD RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 4TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 5TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.1 6TH RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 0.5 1ST RADIO INTERFERENCE |
AHBC | OPERATING CURRENT RATING PER FUNCTION IN AMPS | 1.5 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 1ST RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 2ND RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 3RD RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 4TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 5TH RADIO INTERFERENCE |
AHBL | PRINCIPAL CIRCUITRY TYPE PER FUNCTION | INDUCTANCE-CAPACITANCE 6TH RADIO INTERFERENCE |
AHBN | INPUT TERMINAL MANUFACTURER CODE | 09922 |
AHBP | INPUT TERMINAL IDENTIFICATION | ME26B-1 |
AHBS | OUTPUT TERMINAL MANUFACTURER CODE | 94481 |
AHBT | OUTPUT TERMINAL IDENTIFICATION | DA20418-2 |
AKEJ | MOUNTING FACILITY SCREW THREAD SERIES DESIGNATOR | UNC |
AKNA | INCLOSURE TYPE | HERMETICALLY SEALED |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 1 THREADED HOLE |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, PLUG INPUT 1ST FUNCTION |
CQDW | FUNCTIONAL TERMINAL TYPE AND QUANTITY | 1 CONNECTOR, RECEPTACLE OUTPUT 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 12.0 VOLTS DC 2ND RADIO INTERFERENCE 2ND FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 12.0 VOLTS DC 4TH RADIO INTERFERENCE 4TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 20.0 VOLTS DC 6TH RADIO INTERFERENCE 6TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 25.0 VOLTS DC 1ST RADIO INTERFERENCE 1ST FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 28.0 VOLTS DC 5TH RADIO INTERFERENCE 5TH FUNCTION |
CQGC | OPERATING VOLTAGE RATING AND TYPE PER FUNCTION | 6.0 VOLTS DC 3RD RADIO INTERFERENCE 3RD FUNCTION |
CQJX | NOMINAL THREAD SIZE | 0.164 INCHES |
CQRG | BODY MATERIAL | METAL |
FEAT | SPECIAL FEATURES | TEN FILTERED FUNCTIONS |
STYL | STYLE DESIGNATOR | RECTANGULAR TERMINAL/TERMINALS ON OPPOSITE SURFACES |
RF00201 | RF00200 | RF00200 | RF00200 |
RF00167-2 | RF00167-1 | RF00160 | RF00160 |
RF00160 | RF00158B | RF00158B | RF00158B |
RF00158B | RF00157 | RF00157 | RF00157 |